Home / Products / Comet Cable Glands / Comet Single Compression Type Heavy Duty Cable Gland

Comet Single Compression Type Heavy Duty Cable Gland




Indoor Gland For Single Wire Armoured Cables

Gland reference

Cable dimensions

Gland dimensions

  Diameter Entry thread Across
flats

(E)
Across
corners

(F)
Under
armour
(A)
Overall
Diameter
(B)
Entry

(C)
Length

(D)
size mm mm inch mm mm mm
1616 9.0 15.0 5/8" 8.5 25.0 29.0
1619 10.0 15.0 3/4" 8.5 25.0 29.0
2119 14.0 20.0 3/4" 9.5 30.5 35.0
2125 14.0 20.0 1" 9.5 30.5 35.0
2925 20.0 26.0 1" 10.0 40.0 46.0
2932 24.0 29.0 1.1/4" 10.0 40.0 46.0
2938 24.0 29.0 1.1/2" 10.0 40.0 46.0
3638 31.0 37.0 1.1/2" 11.0 49.0 56.0
4251 36.0 42.0 2" 11.0 60.0 68.0
5451 44.0 50.0 2" 12.0 67.0 77.0
5463 44.0 50.0 2.1/2" 12.0 67.0 77.0
6063 54.0 60.0 2.1/2" 12.0 78.0 88.0
6675 60.0 66.0 3" 13.0 84.0 96.0
7882 70.0 77.0 3.1/4" 14.0 98.0 112.0

Application :
For use under most climatic conditions.This are Weatherproof and may be used in the corrosive conditions when protected by the shroud.

Specification :
Gland consist of checknut 1, gland body 2, metal washers (3 Nos) 3, outer seal rubber ring 4, compression nut 5. All metal parts are made of brass accurately machined for ease of assembly.

Accesories :
Shrouds and Earth tags are supplied separately and should be specified when ordering the gland.

Materials & Finishes :
M.O.C :
a. Cable Gland is manufactured in Brass (standard).
b. Alternate material - Stainless Steel / Aluminium.
Sealing Ring : Natural Rubber
Thread :
a. Glands are supplied with B.S.C. thread (ET) as standard.
b. Alternate thread forms available are - NPT / PG / BSP / MM etc.
Finish : a. Nickel Plated (standard)
b. Alternate Plating - Tin / Cadmium / Chrome
Protection Class : IP 60
Ref Standard : IS 12943



Fiting Sequence

a) Screw item 2 into apparatus (secure with item 1 if plain hole entry.)

b) Pass item 5, item 3 and item 4 over cable before commencing to strip oversheath.

c) Remove the outer sheath to the desired length depending on the length of leads required.

d) Pass item 3 over the cable and splay out the armour wire one by one and then cut the armour wires according to the size of washer. Insert the third metal washer over inner sheath of cable so that bend armour are secured between the two metal washers.

e) Push the cable through item 2 and engage the item 5 with item 2 and tighten up while doing, so the grooved rubber ring will contract in radial direction and will grip the outer sheath of cable.